The Xgard range is a comprehensive selection of fixed point gas detectors that meet the diverse requirements for gas detection in industries throughout the world. This includes many water treatment, oil and gas, power, research facility and manufacturing installations.
Intrinsically Safe (I.S.) or Flameproof (Exd) versions are available, with case options comprising high-grade alloy, stainless steel or chemically resistant GRN polymer. Certifications include IECEx, ATEX, UL and GOST-R.
Crowcon's visual 'traffic light' indication, provides constant visual assurance that T4 is operating soundly and conforms to site bump test & calibration policy. The bright green and red Positive Safety LEDs are visible to all and offer a quick, simple and comprehensive indication of monitor status to both the user and others around them.
Size | Type 1, 2, 3: 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) Type 4: 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) Type 5, 6: 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) |
Weight | Type 1: Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) Type 2, 3: Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs) Type 4: 1.5 kg (3.3lbs) Type 5, 6: Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs) |
Environment | Operating Temperature: Type 1: -40 to +50 °C (-40 to 122 °F) (sensor dependant) Type 2: -20 to +50°C (-4 to 122°F) Type 3: -40 to +80°C (-40 to 176°F) Type 4: -20 to +150°C (-4 to 302°F) Type 5: -40 to +55°C (-40 to 131°F) Type 6: +10 to +55°C (50 to 301°F) Ingress Protection: Type 1, 2, 3: IP65 Type 4: IP54 Type 5, 6: IP65 Humidity: Type 1, 2: 10 to 95% RH non-condensing Type 3, 4, 5: 0-99% RH non-condensing Type 6: 0-90% RH |
Approvals | Type 1: ATEX: II 1 G Exia IIC T4 Ga (Tamb -40 to +55°C) UL/cUL: Class I, Div. 1 Groups A, B, C, D IECEx GOST-R Type 2: ATEX: II 2GD Exd IIC T6 Gb (Tamb -40 to +50°C) UL: Class I, Div. 1 Groups B, C, D IECEx GOST-R Type 3: ATEX: II 2 GD Exd IIC T4 Gb (Tamb -40 to +80°C) Exd IIC T6 Gb (Tamb -40 to +50°C) Ex tb IIIC T180°C Db UL: Class I, Div. 1 Groups B, C, D IECEx GOST-R Type 4: ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) Type 5, 6: ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C) Exd IIC T4 Gb (Tamb -40 to +80°C) Ex tb IIIC T180°C Db UL: Class I, Div. 1 Groups B, C, D IECEx GOST-R |
Enclosure material | Type 1: ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S Type 2, 3: Aluminium or 316 Stainless Steel Type 4: Aluminium Type 5, 6: Aluminium or 316 Stainless Steel Stainless steel: 3.1kg (6.8lbs) |
Electrical output | Type 1, 2: 2- wire 4-20mA (current sink) Type 3: 3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4 Type 4: 3- wire mV bridgeTypical signal: >10mV/%LEL CH4 Type 5, 6: 3- wire 4-20mA (current sink or source) |
Repeatability | Type 1, 2, 3, 4, 5, 6: <2% FSD (Typical)<2% FSD per Month (Typical) |
Response time | Type 1, 2: T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant) Type 3, 4, 5, 6: T90 <15s (Typical) |
EMC Compliance | Type 1, 2, 3, 4, 5, 6: EN 50270 FCC Part 15 ICES- 003 |
Cable entries | Type 1, 2, 3, 4, 5, 6: 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side |
Sensor type | Type 1, 2: Electrochemical Type 3: Catalytic bead Type 4: 316 S/S sensor housing with catalytic beads Type 5: Catalytic bead Type 6: Thermal conductivity |
Terminations | Type 1, 2, 3, 4, 5, 6: 0.5 to 2.5mm2 |
Operating voltage | Type 1, 2: 8-30V dc Type 3, 4: 2.0V dc +/- 0.1V (Typical) Type 5, 6: 10-30V dc |
Power requirements | Type 1, 2: 24mA maximum Type 3, 4: 300mA (Typical) Type 5, 6: 50mA at 24V dc 1.2W |